January 2013 |
|
|
PVD announces AirMover53 three stage cooling application. PVD utilizes ambient air and mechanical cooling to deliver Hybrid cooling at higher temperatures to improve overall PUE scores. |
|
|
Details » |
|
|
|
|
|
Liebert » High Heat Density Cooling Solutions for Racks, Spots and Zones |
|
|
|
Liebert XD Refrigerant-based Cooling Modules |
|
|
Liebert XD refrigerant-based cooling modules work as a system to support the hot aisle/cold aisle approach to cooling high heat density data centers. The modules provide focused rack cooling, enhancing a room precision cooling unit, such as a Liebert DS system. Pumped refrigerant is ideal for use around electronic equipment, operating at low pressure in the piping circuit, and becoming a gas at room conditions. |
|
Liebert XDO overhead cooling module mounts directly above the cold aisle, requiring no floorspace. It draws in hot air from the hot aisle, then discharges cool air into the cold aisle where the equipment air inlets are located. |
|
Liebert XDV rack cooling module mounts vertically on or above the IT rack enclosure, requiring no floorspace. It draws hot air from inside the cabinet or from the hot aisle. It then cools the air and discharges it down to the cold aisle. |
|
Liebert XDH in-row cooling module is placed directly in line with the rack enclosures, and requires very little floorspace. Air from the hot aisle is drawn in through the rear of the unit, cooled, and then discharged horizontally through the front of the unit into the cold aisle. |
|
Liebert XD CoolFrame cooling module is designed to install on the back of the Egenera Bladeframe EX system, providing cooling without increasing the rack footprint. |
|
Flexibility: |
|
|
Cools more than 30 kW per rack. |
|
Requires little or no floor space. |
|
Complements Liebert precision cooling units. |
|
Allows adaptive and scalable expansion without interruption |
|
of cooling operations, with optional pre-charged flexible |
|
piping with threaded quick connect fitting. |
|
Provides models to suit data center needs, mounting on, |
|
above or between the racks. |
|
Provides an excellent solution for spot and zone cooling of |
|
high heat density equipment. |
|
Offers 60 Hz and 50 Hz models. |
|
|
Higher Availability: |
|
|
Uses pumped refrigerant, which is ideal for use around |
|
electronic equipment. |
|
Ensures continuous operation of critical IT systems under |
|
extreme heat conditions. |
|
Includes coil, controls, fans and piping for a complete, |
|
packaged unit. |
|
|
Lowest Total Cost Of Ownership: |
|
|
|
Operates with high energy efficiency. |
|
Offers superior cooling cost per high heat density rack. |
|
Ideally Suited For: |
|
|
Supplemental sensible cooling for high heat density racks |
|
|
|
|
|
|